Menu
Your Cart

Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT

Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
Single Phase RS485 Port Modbus Smart Digital Electric Energy Meter AC 100A Voltage Current Power Frequency Power Meter With Coil CT
$15.99
Ex Tax: $15.99
  • Stock: In Stock
  • Model: EB003281
  • SKU: EB003281

Features:

Not Include the RS485 TO USB Module

This document describes the specification of the PZEM-016 AC communication module,
the module is mainly used for measuring AC voltage, current, active power, frequency, power
factor and active energy, the module is without display function, the data is read through the
RS485 interface

PZEM-016: Measuring Range 100A (external transformer)

1. Function description
1.1 Voltage
1.1.1  Measuring range:80 ~ 260V
1.1.2  Resolution: 0.1V
1.1.3  Measurement accuracy: 0.5%
1.2 Current
1.2.1  Measuring range: 0 ~ 100A(PZEM-016)
1.2.2  Starting measure current: 0.02A(PZEM-016)
1.2.3  Resolution: 0.001A
1.2.4  Measurement accuracy: 0.5%
1.3 Active power
1.3.1  Measuring range: 0 ~ 23kW(PZEM-016)
1.3.2  Starting measure power: 0.4W
1.3.3  Resolution: 0.1W
1.3.4  Display format:
< 1000W, it display one decimal, such as: 999.9W
≥1000W, it display only integer, such as: 1000W
1.3.5  Measurement accuracy: 0.5%
1.4 Power factor
1.4.1  Measuring range: 0.00 ~ 1.00
1.4.2  Resolution: 0.01
1.4.3  Measurement accuracy: 1%
1.5 Frequency
1.5.1  Measuring range: 45Hz ~ 65Hz
1.5.2  Resolution: 0.1Hz
1.5.3  Measurement accuracy: 0.5%
1.6 Active energy
1.6.1  Measuring range: 0 ~ 9999.99kWh
1.6.2  Resolution: 1Wh
1.6.3  Measurement accuracy: 0.5%
1.6.4  Display format:
< 10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh
≥10kWh, the display unit is kWh, such as: 9999.99kWh
1.6.5  Reset energy: use software to reset.
1.7 Over power alarm
Active power threshold can be set, when the measured active power exceeds the threshold, it
can alarm
1.8 Communication interface
RS485 interface

2 2  Communication protocol
2.1 Physical layer protocol
Physical layer use UART to RS485 communication interface
Baud rate is 9600, 8 data bits, 1 stop bit, no parity
2.2 Application layer protocol
The application layer use the Modbus-RTU protocol to communicate. At present, it only
supports function codes such as 0x03 (Read Holding Register), 0x04 (Read Input Register), 0x06
(Write Single Register), 0x41 (Calibration), 0x42 (Reset energy).etc.
0x41 function code is only for internal use (address can be only 0xF8), used for factory
calibration and return to factory maintenance occasions, after the function code to increase 16-bit
password, the default password is 0x3721
The address range of the slave is 0x01 ~ 0xF7. The address 0x00 is used as the broadcast
address, the slave does not need to reply the master. The address 0xF8 is used as the general
address, this address can be only used in single-slave environment and can be used for calibration
etc.operation.
2.3 Read the measurement result
The command format of the master reads the measurement result is(total of 8 bytes):
Slave Address + 0x04 + Register Address High Byte + Register Address Low Byte + Number
of Registers High Byte + Number of Registers Low Byte + CRC Check High Byte + CRC Check
Low Byte.
The command format of the reply from the slave is divided into two kinds:
Correct Reply: Slave Address + 0x04 + Number of Bytes + Register 1 Data High Byte +
Register 1 Data Low Byte + ... + CRC Check High Byte + CRC Check Low Byte
Error Reply: Slave address + 0x84 + Abnormal code + CRC check high byte + CRC check
low byte
Abnormal code analyzed as following (the same below)

Register  address Description Resolution
0x000 Voltage value 1LSB correspond to 0.1V
0x001 Current value high 16 bits 1LSB correspond to 0.001A
0x002 Current value low 16 bits
0x003 Power value high 16 bits 1LSB correspond to 0.1W
0x004 Power value low 16 bits
0x005 Energy value High 16 bits 1LSB correspond to 1Wh
0x006 Energy value low 16 bits
0x007 Frequency value 1LSB correspond to 0.1Hz
0x008 Power factor value 1LSB correspond to 0.01
0x009 Alarm status 0xFFFF is alarm
0x0000 is not alarm


2.5 Reset energy
The command format of the master to reset the slave's energy is (total 4 bytes):
Slave address + 0x42 + CRC check high byte + CRC check low byte.
Correct reply: slave address + 0x42 + CRC check high byte + CRC check low byte.
Error Reply: Slave address + 0xC2 + Abnormal code + CRC check high byte + CRC check
low byte
2.6 Calibration
The command format of the master to calibrate the slave is (total 6 bytes):
0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.
Correct reply: 0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.
Error Reply: 0xF8 + 0xC1 + Abnormal code + CRC check high byte + CRC check low byte.
It should be noted that the calibration takes 3 to 4 seconds, after the master sends the
command, if the calibration is successful, it will take 3 ~ 4 seconds to receive the response from
the slave.
2.7 CRC check
CRC check use 16bits format, occupy two bytes, the generator polynomial is X16 + X15 +
X2 +1, the polynomial value used for calculation is 0xA001.
The value of the CRC check is a frame data divide all results of checking all the bytes except
the CRC check value.
 
5.1 Power supply
AC voltage provides two isolated outputs after through the switching power supply, one way
is 3.3V provides to the measurement system, the other way is 5V provides to 485 communication
circuits and external circuits.
485 communication interface power is(+5 V),current output capability is 100mA
5.2 Working temperature
-20’C ~ +60’C


Package includes:

1 * PZEM-016 AC Communication module
1 * Coil CT


Details pictures:
 




PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578
PEACEFAIR-Single-Phase-RS485-Port-Modbus-Smart-Digital-Electric-Energy-Meter-AC-100A-Voltage-Current-1331578

Write a review

Note: HTML is not translated!
Bad Good

Shipping Time


After you successfully placed an order at RenhotecIC.com, you will receive a confirmation email with your invoice. Once your order is shipped, you will be emailed with the tracking information of your package. Also, you can choose your preferred shipping method during the checkout process. Kindly advise: please select DHL/FedEx if you need our product urgently.

The timeline of the whole shipping process is shown below:

img

The total delivery time is calculated from the time your order is successfully placed to the time received. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s), includes preparing your items, performing quality inspections, and packaging for shipment. Normally, the processing time is 1-3 days (Only include Monday to Saturday ) after getting your order.

Shipping time: The time for your item(s) to travel from our warehouse to your destination. The shipping time depends on the shipping method you chose. Please refer to the shipping rate section for details. 


Shipping Rates


You could choose the shipping method based on your preference during checkout, different shipping methods will apply different rates and shipping times. Please check the following chart for detail:


Shipping MethodShipping RatesShipping Times
Flat Shipping (Promotion)
$10About 5-30 Working Days to Worldwide (Only include Monday to Saturday )

Standard Express(0.5KG starting price listed)

Based On WeightsAbout 5-15 Working Days to Worldwide (Only include Monday to Saturday )

Priority Express (0.5KG starting price listed)

Based On WeightsAbout 3-7 Working Days to Worldwide (Only include Monday to Saturday )

In addition, the transit time depends on where you're located, the shipping method you choose, and where your package comes from. We will keep you informed of any problems here to help you get your order as soon as possible. 

If you want to know more information, please contact the customer service by contact form or sales@renhotecic.com. We will settle your problem as soon as possible. Enjoy shopping!

Tags: Energy Meter